Availability: | |
---|---|
Quantity: | |
This machine is used for testing e-cigarettes, it uses cylinder plunger to simulate people smoke, by setting the smoking duration, smoking volume and smoking times, to judge whether the e-cigarettes are qualified or not. The smoke collection bottle can collect smoke, after testing, the collected smoke or filter can be used for analyzing the chemical composition.
Specification
Product dimension | 1200*610*730mm |
Power supply | AC220V, 50HZ |
Net weight | About 176kg |
Button function | With fixture and fire button |
Supply air source | 0.4~0.8MPa |
Control system | PLC+10.5 inch touch screen |
Suction mode | Sine wave/trapezoidal wave |
Suction speed | 0.1~60ml/s can be set |
Suction volume | 1~100ml (accuracy ± 0.1%) |
Each puff interval | 0.1~999 seconds can be set |
Suction interval | 0.1~999 seconds can be set |
Puff No. | 1~999999 can be set |
content is empty!